Chamber temp warmup fix

This commit is contained in:
Kyle Brown 2023-07-01 02:30:07 +00:00
parent 1ac9cda419
commit 1530ae13e9
2 changed files with 8 additions and 1 deletions

View file

@ -14,7 +14,8 @@ gcode:
M117 Waiting for bed temperature...
TEMPERATURE_WAIT SENSOR=heater_bed MINIMUM={bedTemp} MAXIMUM={bedTemp+1} # Wait for bed temp (within 1 degree)
{% if chamberTemp != 0 %} # If chamber temp set
CHAMBER_WARMER TEMPERATURE={chamberTemp} # Warm chamber
SET_CHAMBER_TEMP CHAMBER={chamberTemp} # Set target chamber temp
CHAMBER_WARMER TEMPERATURE={chamberTemp-5} # Prewarm chamber
{% endif %}
SET_HEATER_TEMPERATURE HEATER=extruder TARGET={hotendTemp|float*0.6} # Set extruder don't drip temp
SET_DOCKABLE_PROBE AUTO_ATTACH_DETACH=1 # Disable probe attach/detach

View file

@ -17,6 +17,12 @@ kick_start_time: 0.5
########## Aliases #########
[gcode_macro SET_CHAMBER_TEMP]
gcode:
{% set chamberTemp = params.CHAMBER|default(0)|int %}
SET_GCODE_VARIABLE MACRO=_BEDFANVARS VARIABLE=target_temp VALUE={chamberTemp}
SET_GCODE_VARIABLE MACRO=_BEDFANVARS VARIABLE=max_temp VALUE={chamberTemp + 5}
[gcode_macro BEDFANSSLOW]
gcode:
# Vars